250-897-6164 rider@fluentenergy.ca
Net Zero renovated home

Existing Home · Net Zero Renovation

A 1970s home, rebuilt for a Net Zero future.

A case-study format that tells the project story first, then gives builders and homeowners the technical detail without feeling like an engineering data sheet.

113 → 0

GJ / YEAR

4.24 → .74

ACH @ 50 PA

12.24 kW

SOLAR PV

All Electric

FUEL SOURCE

The transformation

Before / After

The renovation template gives the visual transformation room to breathe while keeping the energy story immediately understandable.

Home before renovation
Before renovation

113 GJ / year

Existing home performance

→

Home after Net Zero renovation
After renovation

Net Zero

Produces as much energy as it uses annually

How it performs

What changed.

Technical information is grouped into three plain-language areas rather than presented as one dense specification list.

01

Building Envelope

Windows

Triple glazed, dual low-E & argon

Walls

R14 Roxul + R36 exterior reclaimed foam

Ceiling

R50 spray foam / R77 blown-in attics

Airtightness

0.74 ACH @ 50 Pa after renovation

02

Mechanical Systems

Heating + Cooling

Air-source heat pump + electric furnace

Water Heating

Electric heat pump

Ventilation

High-efficiency HRV

03

Renewable Energy

PV System

12.24 kW solar array

Energy Monitoring

Whole-home energy monitor

Result

Annual production offsets annual energy use

Project story

“Net Zero wasn’t one giant leap. Each efficiency decision made the next one possible.”

Performance through practical decisions.

The story section can carry a homeowner, builder or project-team testimonial, followed by a short explanation of the goals, constraints and decisions that shaped the renovation.

Edmonton, AB

Climate Zone 7a

Net Zero Renovation

Energy Advisor

Fluent Energy Consulting

Builder focused. Performance driven.

Net Zero new home

New Home · Net Zero

Designed for high performance from day one.

For a new build, the “before” comparison disappears. The completed home becomes the hero, supported by performance numbers and a clear explanation of how the whole-home system works.

Net Zero

ANNUAL ENERGY TARGET

Step 5

PERFORMANCE TARGET

0.8 ACH

EXAMPLE AIRTIGHTNESS

100%

ELECTRIC PRIMARY SYSTEMS

As-built home

One home. One integrated system.

Lead with strong finished photography, then explain how design, envelope, mechanicals, solar and load management work together.

Annual performance

0 GJ

Example net annual energy consumption after renewable energy production.

1

Cut overall energy use

Smarter design, lower loads and reduced air leakage.

2

High-performance envelope

Insulation, windows and airtightness work together.

3

Go electric

Cold-climate heat pump and efficient electric systems.

4

Size solar to the home

PV matched to modeled annual demand.

5

Manage loads intelligently

Plan for storage, EV charging and future resilience.

Project details

At a glance.

This area can be populated directly from the project’s EnerGuide / Net Zero documentation and the Fluent Energy brochure content.

Project Team

Builder

Builder Name

Energy Advisor

Rider Petch · Fluent Energy Consulting

Location

Comox Valley, BC

Envelope

Windows

High-performance triple glazing

Wall / Roof

Project-specific assemblies

Airtightness

Final blower-door result

Systems + Solar

Space Conditioning

Cold-climate heat pump

Hot Water

Heat-pump water heater

Solar

Project-specific PV capacity

Why it matters

Comfort, durability and lower energy use — without making high performance feel complicated.

Built better from the start.

A short case-study narrative can explain the builder’s goals, key design decisions, any challenges solved during construction, and the final measured performance.

Net Zero

All Electric

Solar Ready

High Performance

Fluent Energy Consulting

Build better. Build Net Zero.